Shenzhen Healthy Technology co.,ltd
|
Place of Origin: | Zhejiang, China (Mainland) |
Add to My Favorites | |
HiSupplier Escrow |
Low - voltage Mini Fingertip Pulse Oximeter with Spo2 Oximetry Display
Quick Detail:
*Integrated with SpO2 probe and processing display module
*Small in volume,light in weight and convenient in carrying
*Operation of the product is simple ,low power consumption
*SpO2 value display
*Pulse rate value display, bar graph display
*Low-voltage indication: low-voltage indicator appears before working abnormally which is due to low-voltage
*Automatically power off function: when the device is under the state of measuring interface . it will automatically power off within 5 seconds if the finger falls out of probe.
Description:
Display Mode:LED display
SpO2 Measuring Range:0%~100%, (the resolution is 1%).
Accuracy:70%~100%:+/-2% ,Below 70% unspecified.
PR Measuring Range:30bpm~250bpm, (the resolution is 1bpm)
Accuracy:+/-2bpm or +/-2% (select larger)
Measurement Performance in Weak Filling Condition:SpO2 and pulse rate can be shown correctly when pulse-filling ratio is 0.4%. SpO2 error is +/-4%, pulse rate error is +/-2 bpm or +/-2% (select larger).
Resistance to surrounding light: The deviation between the value measured in the condition of man-made light or indoor natural light and that of darkroom is less than +/-1%.
Power Consumption:less than 25mA
Voltage:DC 2.6V~3.6V
Power Supply:1.5V (AAA size) alkaline batteries * 2
Battery working hour:The minimum continually work time is 24 hours ,theoretical number is
56 hours.
Safety Type:Interior Battery,BF Type
Qualification
Passed CE,FDA
Applications:
The product is suitable for being used in family, hospital, oxygen bar, community healthcare, physical care in sports (It can be used before or after doing sports, and it is not recommended to use the device during the process of having sport) and etc.
Specifications:
Display Mode: |
LED display |
SpO2 Measuring Range: |
0%~100%, (the resolution is 1%). |
Accuracy: |
70%~100%:±2% ,Below 70% unspecified. |
PR Measuring Range: |
30bpm~250bpm, (the resolution is 1bpm) |
Accuracy: |
±2bpm or ±2% (select larger) |
Competitive Advantage:
High quanlity
Best Price
professonal express service